更快發現隱形聲學問題

Hertzinno

快速場診斷

在螢幕上直接視覺化異常聲音來源,減少現場檢查期間的故障排除時間。
View More
Hertzinno

電力設備檢查

尋找變電站、開關室和電力設備中的電暈、電弧和局部放電電源。
View More
Hertzinno

洩漏定位

利用聲學成像引導檢測壓縮空氣、真空、SF6 或工業氣體洩漏源。
View More
Hertzinno

維護報告

為檢查組提供視覺證據、位置資訊和現場核實記錄。

手持式聲學攝影機的使用地點

手持式聲學攝影機適用於需要快速、直覺且可重複診斷的移動偵測團隊。
定位電氣設備中的局部放電、電暈和異常超音波發射。
尋找加壓氣體洩漏、甲烷相關洩漏源和管道閥門洩漏點。
檢測生產設施中的壓縮空氣洩漏、真空洩漏和異常聲源。

選擇合適的手持式聲學攝影機

根據您的檢測目標選擇型號:放電檢測、氣體洩漏檢測、熱驗證、危險區域檢測或遠距離檢測。
Contact Us
用於氣體洩漏檢測、局部放電檢測和識別以及異常聲音定位的便攜式聲學成像技術。
結合聲學成像和熱成像技術,用於電氣檢測和工業故障排除。
專為石油、天然氣和化學工業的天然氣洩漏定位和濃度測量而設計。
Handheld Acoustic Cameras | 144-Channel PD & Gas Leak Detectors | Hertzinno

HA3LX: Handheld Acoustic & Methane Laser Camera

Integrating acoustic imaging with Tunable Diode Laser Absorption Spectroscopy (TDLAS) for complex environments.

  • Core Sensors: 144 Low-noise MEMS Microphones and a Methane Laser Sensor.
  • Methane Quantification: Non-contact real-time measurement of methane concentration with a static detection limit of 5ppm*m and up to 30m detecting distance.
  • Dual-Detection Approach: Verifies and quantifies the presence of methane at the leak point once localized by the acoustic camera.
  • Safety Compliance: ATEX Anti-explosion certified (Ex ib IIIC T130°C Db / Ex ib IIC T4 Gb).

HA3T: Handheld Acoustic & Thermal Camera

Combining high-resolution acoustic localization with infrared thermal imaging for multi-dimensional defect analysis.

  • Core Sensors: 144 Low-noise MEMS Microphones paired with a 640x512 Infrared lens.
  • Thermal Capabilities: Spectral range of 8~14μm (LWIR) with NETD ≤40mK, measuring temperatures from -20°C to 150°C and 100°C to 550°C.
  • Advanced PD Analysis: Intelligent analysis of partial discharge types combined with real-time sound source localization.
  • Spatial Precision: Achieves spatial resolution of ≤1cm error at 1m distance under 40kHz.

On-Device Diagnostics & UI

High-Definition Interface

Features a 5-inch touch screen (1920*1080P) displaying 13MP optical camera images and supporting up to 4K photo resolution.

Real-Time Analytics

Supports one-click analysis, one-click forwarding, and the real-time generation of analysis reports directly on the device.

Data Management

Comprehensive file annotation using text, voice, photos, and tags. Export capabilities via Wi-Fi, Bluetooth, or USB Type-C.

Technical Specifications

Specification HA3LX (Methane Laser Model) HA3T (Thermal Model)
Microphones 144 Digital MEMS Microphones 144 Digital MEMS Microphones
Frequency Bandwidth 2kHz - 150kHz 2kHz - 150kHz
Operating Distance 0.3m - 200m 0.3m - 200m
Optical Camera 13MP, 72°±3° FOV 13MP, 72°±3° FOV
Display 1920*1080P, 5-inch, Touch Screen 5-inch, Touch Screen, 1920*1080
Specialized Sensor TDLAS Methane Sensor (0 to 50,000 ppm*m) 640*512 Uncooled Vanadium Oxide Infrared Lens
Laser Distance Measurement 0.1-35m 0.1-35m(±1mm)
Protection Level IP54, ATEX Anti-explosion IP54
Weight Less Than 1.2kg Less than 1.2kg
Battery & Charging Li-ion, 2.5 H to 90% PD Fast Charging Li-Ion, up to 7 hours, PD Fast Charging
FAQ

Acoustic Imaging Camera FAQ

Common questions about acoustic cameras for gas leak detection, partial discharge inspection, methane verification, thermal imaging and fixed online monitoring.

What is an acoustic imaging camera?

An acoustic imaging camera uses a microphone array to locate sound sources and display them as a visual sound map. It helps engineers find invisible faults such as gas leaks, partial discharge and abnormal mechanical noise.

What can HERTZINNO acoustic cameras detect?

HERTZINNO acoustic cameras can help detect pressurized gas leaks, compressed air leaks, partial discharge, corona, tracking, mechanical noise, abnormal equipment sound and methane-related leak risks depending on the selected model.

How do I choose between HA3, HA3T and HA3LX?

Choose HA3 for general acoustic inspection, HA3T when thermal verification is also required, and HA3LX when methane verification is needed in oil, gas or chemical environments.

When should I use a fixed online acoustic camera?

Fixed online acoustic cameras are suitable for unmanned substations, compressor stations, data center electrical rooms, hazardous industrial zones and other sites that need continuous monitoring instead of periodic manual inspection.

Can acoustic cameras work in noisy industrial environments?

Yes. Acoustic cameras analyze frequency features and directional sound sources rather than relying only on audible sound. Models and settings should be selected based on background noise, target frequency range and inspection distance.

Which industries use acoustic imaging cameras?

Common industries include power grids, substations, oil and gas facilities, chemical plants, data centers, manufacturing lines, mining operations, hydrogen systems and critical infrastructure sites.

Key Applications & Demos

Partial Discharge Detection

Precisely locate PD sources (±15cm) from 200m away. Automatically classifies discharge types (Corona, Surface, Internal) and assesses severity using PRPD mapping to prevent failures.

Gas Leak & Cost Analysis

Detects leaks in Compressed Air, Hydrogen, SF6, and Natural Gas (20-100 kHz). Built-in AI estimates leakage volume and calculates annual energy loss costs in real-time.

Mechanical Fault Diagnosis

Visualize sound maps to identify bearing damage, blade imbalance, and misalignment in motors and fans. Pinpoints the exact location of faults to shorten troubleshooting time.

We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.