HZ-OLF-100

No.HZ0601001

The Hertzinno HZ-OLF-100 is an intelligent transmission line fault locating system designed for precise interval fault positioning without the need for external public network coverage. Utilizing a private wireless infrastructure, the system provides a robust solution for monitoring 6kV to 500kV lines in remote mountainous, desert, or high-altitude environments where 4G/5G signals are unavailable.

Applicable Voltage
5kV - 500kV
Networking Frequency
433.92MHz (Private Wireless)
Alarm Trigger Time
30ms
Max Operating Current
20kA / 2s
Operating Temperature
-25°C to 70°C
Protection Rating
IP67
  • Overview

  • Download

Advanced Detection & Warning Capabilities

  • Comprehensive Fault Detection: Precisely identifies short-circuit faults, ground faults, poor contact faults, and insulator faults.
  • Self-Organizing Network: Features high-level network adaptability, allowing the system to maintain a stable connection through its own architecture from sensing to the management platform.
  • Intelligent Warning Types: Provides alerts for crown close-range discharge, floating object contact (excluding plastic), and monitors asynchronous actions in three-phase switches.
  • Zero False Alarms: Utilizes a passive sampling mode that operates only when activated by fault current pulses, physically eliminating interference-driven false reports.
  • Private Wireless Communication: The system utilizes a 433.92MHz private wireless frequency for data transmission between terminal sensors and substations, eliminating monthly communication fees and vulnerability to public signal outages.

Key Technical Advantages

  • Broad Voltage Range: Fully supports transmission and distribution lines from 5kV up to 500kV.
  • Long-Range Coverage: Each terminal sensor effectively covers a line distance of up to 5km (3 miles).
  • Triple-Source Power Supply: Terminals are powered by solar energy, current-induced power harvesting, and an internal battery for long-term stability.
  • Environmental Resilience: Features an IP67 protection rating and operates reliably in temperatures ranging from -25°C to 70°C.
  • Hertzinno grid monitoring solution
  • HZ-OLF-100,Hertzinno,HZ-OLF-100 Overhead Line Fault Indicator | Transmission Line Monitoring | Hertzinno
  • line fault indicator
  • HZ-OLF-100,Hertzinno,HZ-OLF-100 Overhead Line Fault Indicator | Transmission Line Monitoring | Hertzinno
  • Line fault indication system
Leave a message
Your Name*
Company Name*
Email*
Message*
Country*
Code*
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.